FPL net metering and solar buyback
Published November 16, 2026. Rules checked November 16, 2026.
- Net metering Florida: Net Metering of Customer-Owned Renewable Generation (Tariff Sheet No. 10.010). Excess kWh credited 1:1 to the next month.12
EIA counted 119,543 residential net-metering installations at FPL at the end of 2025.3
Tariffs checked November 16, 2026; EIA-861 2025 final data, released October 7, 2026.
Source: Energy Information Administration, Form EIA-861 Annual Electric Power Industry Report, 2025 final data; Census Bureau, Cartographic boundary files, states. States shaded by their program type; EIA-861 2025 rows of the utility.
Show the numbers
| State | Residential installations |
|---|---|
| Florida (Florida Power & Light Co) | 119,543 |
Florida Power & Light buys back rooftop solar through net metering. Excess kilowatt-hours sent to the grid in a billing cycle are credited against the next month's energy use, so each one cancels a kilowatt-hour you would otherwise buy. In the last billing cycle of the year, FPL credits any unused kilowatt-hours at an average annual rate based on its COG-1 As-Available Energy Tariff, which is far lower than retail.1
How FPL credits your solar
FPL's net metering terms sit in its electric tariff, on Sheet No. 10.010, effective January 1, 2026. They apply to customers with renewable generation up to 2 MW who have signed FPL's Interconnection Agreement for Customer-Owned Renewable Generation.1
The mechanics are monthly. If the system delivers more energy to FPL's grid than the home uses during a billing cycle, the excess is credited to the customer's energy consumption in the next month's billing cycle.1 Because the credit is in kilowatt-hours, an exported kWh cancels an imported kWh at whatever energy price your rate charges. Credits carry forward month to month.
In the last billing cycle month of each calendar year, unused credits for excess kWh are credited using an average annual rate based on FPL's COG-1 As-Available Energy Tariff, and the same rate applies to credits left when an account closes.1 That annual rate tracks the utility's avoided energy cost, so it is well below the retail price. The design rewards a system sized to the home's yearly use.
| Rule | What applies |
|---|---|
| Program type | Net metering |
| Program | Net Metering of Customer-Owned Renewable Generation (Tariff Sheet No. 10.010) |
| Export credit | Excess kWh credited 1:1 to the next month12 |
| Netting interval | Monthly |
| Unused credits and charges | Unused kWh credited in the last billing cycle of each calendar year at the average annual COG-1 as-available energy rate |
A year on FPL net metering
The worked example below runs one illustrative FPL household through these rules with the same code as our export credit calculator. The household's inputs are on the figure. The energy price is Florida's average residential price over the last 12 months, which includes fixed charges; the energy rate on an FPL bill is lower, so try your own bill's numbers in the calculator.
Inputs: 1,300 kWh a month of use; 11,000 kWh a year of solar output spread over the months as PVWatts models for Florida; 35% of output used at home as it is produced; energy price 15.41¢ per kWh (the Florida average residential price over the 12 months to August 2026, which includes fixed charges).
| Solar production in a year | 11,000 kWh |
|---|---|
| Used at home as it is produced | 3,850 kWh |
| Sent to the grid (exports) | 7,150 kWh |
| Bought from the grid (imports) | 11,750 kWh |
| Value of solar used at home, at your energy price | $593 |
| Exports credited 1:1 against imports (kWh) | 7,150 kWh |
| Leftover exports at year end (kWh) | 0 kWh |
| Value of exports under this tariff | $1,102 |
| Average credit per exported kWh | 15.41¢ |
| Energy charges for a year without solar | $2,404 |
| Energy charges for a year with solar, before fixed charges | $709 |
| Minimum monthly bill in the tariff | $30.00 |
Source: National Laboratory of the Rockies (formerly NREL), PVWatts v8 model estimates; Energy Information Administration, Electricity retail sales, residential average price. Export treatment from the tariff cited in the text (Unused kWh are paid each December at FPL’s average annual COG-1 as-available rate; enter it if you have it.). An illustration of the crediting rule, not a quote or a savings estimate: fixed charges, minimum bills, taxes and time-of-use prices are not modelled. Try your own numbers in the export credit calculator.
Two things stand out. Exports offset imports one for one until production catches up with use, so the value of an exported kWh and a self-consumed kWh is the same for most of the year. And a system that produces more than the home uses gains little from the extra, because leftover credits are paid at the lower COG-1 based annual average; if a past December bill shows that rate, enter it in the calculator.
The minimum bill and base charge
Net metering lowers the energy part of the bill, not the fixed part. FPL's residential rate RS-1 has a base charge of $10.52 a month and a minimum charge of $30.00.2 The net metering clause adds that, regardless of whether excess energy is delivered to the grid, the customer pays the greater of the rate's minimum charge or its base charge plus any demand charge.1
For most solar homes the minimum only bites in months when credits cover nearly all the energy charges. A household whose panels cover its usage almost every month will still see a monthly bill.
Applying and interconnecting
FPL follows the Florida Public Service Commission's rule on customer-owned renewable generation, which sorts systems into three tiers: Tier 1 up to 10 kW, Tier 2 above 10 kW up to 100 kW, and Tier 3 above 100 kW up to 2 MW. A system's capacity may not exceed 90% of the customer's distribution service rating.7
Most home systems fall in Tier 1, and Tier 1 customers may not be charged fees in addition to those charged to other retail customers without self-generation, including application fees.7 Tier 2 and Tier 3 systems also require proof of liability insurance and an application fee, and FPL says systems of 50 kW or more need three-phase service.8
The official application steps are on FPL's net metering page. Florida's statewide rule, which also binds Duke Energy Florida and the state's other investor-owned utilities, is explained on our Florida net metering page.
FPL solar by the numbers
FPL reported 119,543 residential net-metering installations to EIA at the end of 2025, with 1,100 MW of residential capacity. That is 37% of all net-metered homes in Florida and the 7th3 largest count of any US utility in a single state.
Source: Energy Information Administration, Form EIA-861 Annual Electric Power Industry Report, 2025 final data. EIA-861 utility rows, all technologies; utility names as reported to EIA.
Show the numbers
| Utility | Residential installations |
|---|---|
| Florida Power & Light Co | 119,543 |
| Duke Energy Florida, LLC | 103,920 |
| Tampa Electric Co | 33,361 |
| Orlando Utilities Comm | 11,443 |
| Lee County Electric Coop, Inc - (FL) | 10,389 |
| Sumter Electric Coop, Inc | 6,844 |
| JEA | 6,592 |
| Withlacoochee River Elec Coop | 5,638 |
| Kissimmee Utility Authority | 4,423 |
| Clay Electric Cooperative, Inc - (FL) | 3,287 |
| City of Lakeland - (FL) | 2,130 |
| Gainesville Regional Utilities | 1,587 |
| Peace River Electric Coop, Inc | 1,468 |
| City of Tallahassee - (FL) | 1,334 |
| Talquin Electric Coop, Inc | 1,057 |
| City of Ocala | 808 |
| Utility Board of the City of Key West, F | 726 |
| Florida Public Utilities Co | 623 |
| Choctawhatche Elec Coop, Inc | 572 |
| City of Leesburg - (FL) | 429 |
| Beaches Energy Services | 361 |
| City of Homestead - (FL) | 350 |
| City of Bartow - (FL) | 343 |
| City of Lake Worth Beach - (FL) | 333 |
| New Smyrna Beach City of | 308 |
| Glades Electric Coop, Inc | 297 |
| Florida Keys El Coop Assn, Inc | 258 |
| Fort Pierce Utilities Authority | 254 |
| Gulf Coast Electric Coop, Inc | 254 |
| City of Winter Park - (FL) | 231 |
| West Florida El Coop Assn, Inc | 227 |
| Central Florida Elec Coop, Inc | 223 |
| Suwannee Valley Elec Coop Inc | 219 |
| Tri-County Electric Coop, Inc (FL) | 152 |
| Okefenoke Rural El Member Corp | 119 |
| Escambia River Elec Coop, Inc | 117 |
Florida's net-metered homes have grown quickly, from 90,4339 customers of all kinds in 2020 to 325,0253 in 2025.
Federal tax credit
An FPL customer who buys a system now does so without the federal homeowner credit. It is gone for installations completed after December 31, 2025, because §25D treats an expenditure as made when installation is completed.10 The federal solar tax credit page covers 2025 installations, carryforwards and leases.
Questions and answers
Does FPL buy back solar power?
Yes, through net metering. Excess energy delivered to FPL's grid during a billing cycle is credited to the customer's energy consumption for the next month's billing cycle.1
How much does FPL pay for excess solar?
Within the year, an exported kWh offsets a kWh you would otherwise buy, so it is worth the retail energy price. Credits still unused in the last billing cycle of the calendar year are credited at an average annual rate based on FPL's COG-1 As-Available Energy Tariff.1
Is there a minimum bill for FPL solar customers?
Yes. Whether or not you export, you pay the greater of your rate schedule's minimum charge or its base charge plus any demand charge.1 On residential rate RS-1 the minimum is $30.00 a month.2
How large a system can I net meter with FPL?
Up to 2 MW with an executed Interconnection Agreement for Customer-Owned Renewable Generation.1
Does FPL charge an application fee for home solar?
Not for Tier 1 systems up to 10 kW: the Florida rule bars fees beyond those charged to customers without solar, including application fees.7 Tier 2 and Tier 3 systems pay an application fee and must show liability insurance.8
Related pages
Sources
- FPL Electric Tariff Section 10 – Eighteenth Revised Sheet No. 10.010 "Contract Provisions – Various" (Net Metering of Customer-Owned Renewable Generation), Sheet No. 10.010, effective January 1, 2026.
For Customers with renewable generation equipment up to a maximum of 2 MW that have executed an Interconnection Agreement for Customer-Owned Renewable Generation with the Company, the following billing parameters will apply. … If any excess customer-owned renewable generation is delivered to the …
Checked November 16, 2026. fpl.com - FPL Electric Tariff Section 8 – Sixty-Third Revised Sheet No. 8.201, Rate Schedule RS-1, Sheet No. 8.201, effective January 1, 2026.
MONTHLY RATE: Base Charge: $10.52 ... Minimum: $30.00
Checked November 16, 2026. fpl.com - Energy Information Administration, Form EIA-861 Annual Electric Power Industry Report, 2025 final data, Net_Metering_2025.xlsx (f8612025.zip), released October 7, 2026. eia.gov
- Census Bureau, Cartographic boundary files, states, cb_2025_us_state_20m. census.gov
- National Laboratory of the Rockies (formerly NREL), PVWatts v8 model estimates, Typical-year weather (NSRDB), state mean center of population. pvwatts.nlr.gov
- Energy Information Administration, Electricity retail sales, residential average price, electricity/retail-sales, sector RES, released October 23, 2026. eia.gov
- Florida PSC Rule 25-6.065, F.A.C., Interconnection and Net Metering of Customer-Owned Renewable Generation (as adopted by Order No. PSC-08-0161-FOF-EI, Docket 070674-EI; copy hosted by FPL), Rule 25-6.065 F.A.C..
Tier 1 customers who request interconnection of customer-owned renewable generation shall not be charged fees in addition to those charged to other retail customers without self-generation, including application fees.
Checked November 16, 2026. fpl.com - FPL Net Metering FAQ, FPL web page.
Tier 2, (10 to 100 kW) and Tier 3 (100 kW to 2 MW) systems also require proof of liability insurance and an application fee.
Checked November 16, 2026. fpl.com - Energy Information Administration, Form EIA-861 Annual Electric Power Industry Report, net metering 2010–2025, Net_Metering sheets of the annual files, released October 7, 2026. eia.gov
- 26 U.S.C. §25D, Residential clean energy credit, Text current through Public Law 119-142 (November 10, 2026).
in the case of property placed in service after December 31, 2021, 30 percent … The credit allowed under this section shall not apply with respect to any expenditures made after December 31, 2025. … an expenditure with respect to an item shall be treated as made when the original installation of …
Checked November 16, 2026. uscode.house.gov
Rules are quoted from the official text and dated; how we check them: methodology. Not legal or tax advice. Found an error? Write to [email protected]; corrections are listed on the updates page.